Output currency : 2,4A-0.32A
Rated power : 12W -15.4W
Input frequency : 47 ~ 63Hz
DC voltgae : 5V-48V
Efficiency : 80% -87%
Protection : over voltgae / over load
Dimension : 192*178*45.5mm (L*W*H)
Weight : 0.98kg
Mean Well HDR series HDR-15 HDR-30 HDR-60 HDR-100
Mean Well Portable Type Metal Enclosure Charger NPB-120-12 NPB-120-24 NPB-120-48
Model
New models:
NPB-120 / NPB-240 / NPB-360
Old models:
PA-120 / PB-120
Standard type highly reliable wide voltage range charger
Metal enclosure for better heat dissipation , leading lower touch temperature
Easy and flexible adjustment:
‧ Charging voltage adjustable through front panel (10.5~15.2V, 21~30.4V, 42~60.8V)
‧ Charging current adjustable through panel (50~100% of rated current)
‧ 2 or 3 stage selectable by DIP S.W. on front panel
Protections: Short circuit, over voltage, over temperature, battery reverse polarity
Comply with UL/EN62368-1 and IEC60335-1/2-29 dual certifications
Multiple DC output plugs selectable: Anderson, terminal block and 4 pin power pin
Technical
MODEL | HDR-15-5 | HDR-15-12 | HDR-15-15 | HDR-15-24 | HDR-15-48 | |||
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 48V | ||
RATED CURRENT | 2.4A | 1.25A | 1A | 0.63A | 0.32A | |||
CURRENT RANGE | 0 ~ 2.4A | 0 ~ 1.25A | 0 ~ 1A | 0 ~ 0.63A | 0 ~ 0.32A | |||
RATED POWER | 12W | 15W | 15W | 15.2W | 15.4W | |||
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | |||
VOLTAGE ADJ. RANGE | 4.5 ~ 5.5V | 10.8 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 29V | 43.2 ~ 55.2V | |||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
SETUP, RISE TIME | 2000ms, 80ms/230VAC 2000ms, 80ms/115VAC at full load | |||||||
HOLD UP TIME (Typ.) | 30ms/230VAC 12ms/115VAC at full load | |||||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational ) | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
EFFICIENCY (Typ.) | 80% | 85% | 85.5% | 86% | 87% | |||
AC CURRENT (Typ.) | 0.5A/115VAC 0.25A/230VAC | |||||||
INRUSH CURRENT (Typ.) | COLD START 25A/115VAC 45A/230VAC | |||||||
PROTECTION | OVERLOAD | 110 ~ 145% rated output power | ||||||
Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE | 5.75 ~ 6.75V | 14.2 ~ 16.2V | 18.8 ~ 22.5V | 30 ~ 36V | 56.5 ~ 64.8V | |||
Protection type : Shut off o/p voltage, clamping by zener diode | ||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ (Refer to "Derating Curve") | ||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) RH non-condensing | |||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | |||||||
OPERATING ALTITUDE | 2000 meters | |||||||
OVER VOLTAGE CATEGORY | Ⅲ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters | |||||||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC 004, BSMI CNS14336-1 approved; Design refer to TUV BS EN/EN62368-1 | ||||||
WITHSTAND VOLTAGE | I/P-O/P:4KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||
EMC EMISSION | Parameter | Standard | Test Level / Note | |||||
Conducted | BS EN/EN55032(CISPR32), CNS13438 | Class B | ||||||
Radiated | BS EN/EN55032(CISPR32), CNS13438 | Class B | ||||||
Harmonic Current | BS EN/EN61000-3-2 | Class A | ||||||
Voltage Flicker | BS EN/EN61000-3-3 | ------- | ||||||
EMC IMMUNITY | BS EN/EN55024, BS EN/EN55035, BS EN/EN61000-6-2, BS EN/EN61204-3 | |||||||
Parameter | Standard | Test Level /Note | ||||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air; Level 2, 4KV contact, criteria A | ||||||
Radiated Susceptibility | BS EN/EN61000-4-3 | Level 3, criteria A | ||||||
EFT/Burest | BS EN/EN61000-4-4 | Level 3, criteria A | ||||||
Surge | BS EN/EN61000-4-5 | Level 4,2KV/L-N, criteria A | ||||||
Conducted | BS EN/EN61000-4-6 | Level 3, criteria A | ||||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4, criteria A | ||||||
Voltage Dips and interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods | ||||||
OTHERS | MTBF | 3724.3K hrs min. Telcordia SR-332 (Bellcore) ; 1166.1K hrs min. MIL-HDBK-217F (25℃) | ||||||
DIMENSION | 17.5*90*54.5mm (W*H*D) | |||||||
PACKING | 78g;160pcs/13.5Kg/1.14CUFT |