Sign In | Join Free | My uabig.com |
|
Brand Name : Eltek
Model Number : CTE30834R1.4000
Certification : CE.UL
Place of Origin : CN
MOQ : 1
Payment Terms : L/C,T/T
Supply Ability : 400 sets /month
Delivery Time : 8-10 weeks
Type : Outdoor Rectiverter cabinet
External size : customized
Product name : Outdoor cabinet
Application : Telecom, Railway Station, base station; Outdoor cabinet for BTS
Size : Type 3 (1.5m/2m /2.2m )
Service : OEM or ODM
Cooling system : Aircon or heat exchanger
Warranty : 3 years
Structure : Steel structure
Surface finish : painting
Ip rating : IP65 outdoor cabinet
Open side : Front operation
Eltek Rectiverter Outdoor system 6 kVA AC up to 21KW 48Vdc Output AC DC rectiverter outdoor cabinet (CTE30834R1.4000 )
The Rectiverter outdoor system combines both AC and DC feed into one common unit. Simultaneously it provides AC backup power for 230 Vac loads, and 48 Vdc power for DC loads and battery charging.
With our Type 3 cabinet platform it’s designed for a protection class of IP55. The total DC output can be configured up to 21kW DC load where the limitation for AC load is set to max 6kVA.
Parameters :
Models / ordering information 6kVA+12,8 kW DC | 6kVA+16,8kW DC | 6kVA+ 16,0 kW DC | 6kVA+21,0kW DC | ||
Part number CTEJ0834.4000 | CTEJ0834.4001 | CTE20834R1.4000 | CTE30834R1.4000 | ||
AC OUTPUT DATA | |||||
Voltage (default) / (adjustable range) 230 VAC / 200 - 240 VAC | |||||
Frequency (default inverter mode) 50 Hz (adaptive) | |||||
Frequency (set-able inverter mode) 50Hz, 60Hz or last synced 50/60Hz (adaptive) | |||||
Power maximum (continuous / overload (<15s) ) 4800 W (6000 VA) / 8000 VA | |||||
Current maximum (continuous / overload (<15s) ) 26ARMS / 34,8ARMS | |||||
Current (maximum) Quick trip (20ms) 120A (6 x nominal) | |||||
Hold up (Voltage dips) (before switching to > 5 ms @ 4800W load battery) | |||||
THD < 1.5 % at resistive load | |||||
Output features Fuse in L and N, Hot pluggable | |||||
DC OUTPUT DATA | |||||
Voltage (default) / (adjustable range) 53.5 VDC / 43 - 58 VDC | |||||
Power (maximum @nominal input) 12,8 kW 1) | 16,8 kW 1) | 16,0 kW 1) | 21,0 kW 1) | ||
Current (maximum @VOUT ≤ 48 VDC) 267 A 1) | 350 A 1) | 333 A 1) | 437 A 1) | ||
Hold up time, maximum output power >10ms; VOUT > 41 VDC | |||||
Output features Short circuit proof, Over voltage Shutdown | |||||
INPUT DATA | |||||
AC Mains Input Voltage (3 phase Y) 400 VAC | |||||
Surge Protection OVP Class 2 | |||||
AC Current/Phase(at nominal output voltage) (depending on type) 28-58 ARMS 3) | |||||
Frequency (default: sync range) 47-53 Hz | |||||
Frequency (set-able: sync range) 47-53 Hz, 57-63 Hz or both (adaptive) | |||||
Power Factor / THD > 0.99 at 50% load or more / < 3.5% | |||||
DC Voltage nominal / extended range (no 45 - 58 V / 40 - 45 V overload)2) DC DC | |||||
DC Current (maximum) 128 A / 180A during overload (15s) | |||||
Fuse in L and N, Hot pluggable, Varistor, Hot pluggable Input features AC input individual screw terminals 10 mm2 for L1, L2, L3, N & PE Battery breaker (plug-in type), LVBD default | |||||
LOAD DISTRIBUTION 6kVA+12,8kW DC | 6kVA+16,8kW DC | 6kVA+16,0 kW DC | 6kVA+21,0 kW DC | ||
LVLD 150 A | - | ||||
1 pole AC distribution (L connection on MCB) 2*6A, 2*10A C | |||||
-48 VDC distribution ( priority load ) 2*10A,2*16A,2*32A,2*63A | 2*10A, 2*32A,2*63A | 2*10A,2*16A,2*32A,2*63A | 2*10A,2*16A,3*32A,3*63A | ||
-48 VDC distribution (no priority load) 2*10A, 2*32A, 2*63A | - | ||||
Battery breaker 2*100 A, D (plug-in) | 2*200 A, D (plug-in) | 2*200 A, D (plug-in) | 2*250 A, D (plug-in) | ||
OTHER SPECIFICATION | |||||
Control and monitoring (see Smartpack2 datasheet) Smartpack S panel mount | Smartpack 2 | ||||
Efficiency >96% (mains mode (AC/AC and AC/DC)), >94% (inverter mode (DC/AC)) | |||||
Operating temperature -40 to +55°C (-40 to +131°F), humidity 5 - 95% RH non-condensing | |||||
Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing | |||||
Dimensions[WxDxH] / Weight 700 x 823x 1800mm (27,6 x 32,4 x 71”) / 250kg (551 lbs) | |||||
Protection class IP 55 | |||||
Colour RAL 7035 | |||||
DESIGN STANDARDS | |||||
Electrical safety EN 60950-1, EN 62040-1 UPS safety | |||||
EMC ETSI EN 300 386 V.1.6.1, FCC CFR 47 Part 15 EN 61000-6-1 /-2/-3/-4 | |||||
Environment ETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3) & 2-3 (Class 3.2) RoHS (2011/65/EU) and WEEE (2002/96/EC) compliant | |||||
1) AC load has priority. Maximum available DC output power and current is dependent on 3) If DC voltage is pulled below 43V the input current may increase above this level instant AC load and AC input voltage; i.e maximum 10,9 kW/18,9 kW at full AC power and nominal input for 230VAC. 2) 40 - 45 VDC: reduced performance - no power boost and increased voltage THD on AC output |
* The Outdoor Rectiverter Cabinet with AC &DC feed in one cabinet ( Eltek Type 3 cabinet with different PowerCore)
POWERCORE for choice
Solutions
Wandering through the poetic garden of telecommunications, we sow the fragrance of services for telecom companies at home and abroad. From the careful observation during the site survey to the professional solutions tailored for customers, from the ingenious resolution of technical problems to the meticulous care of system equipment, we nurture the flower of telecommunications with love and professionalism. Behind us are a talented team and a circle of dear friends as partners around the world, enjoying the blossoming prosperity of telecommunications together.
FAQ :
1.How do you maintain product quality?
2.What's the lowest quantity I can order?
3.Could you share some details about your company?
4.What makes your company special?
5.Can I obtain samples and a price list?
![]() |
Railway Station 21KW 48Vdc BTS Outdoor Telecom Cabinets OEM ODM Images |